Product Details:

  • Voltage 230 V AC
  • Frequency 50/60 Hz
  • Accuracy High precision; typically <2% RSD for standard solutions
  • Measurement Range ppb to ppm concentrations for a wide range of elements
  • Core Components Graphite furnace atomizer, Zeeman background correction system, optical bench, power supply unit
  • Power Source AC Mains Electricity
  • Model No ZEEnit 650P
  • Click to View more
X

Analytikjena ZEEnit 650P Furnace Vision Graphite Furnace AAS with Zeeman background correction Price And Quantity

Analytikjena ZEEnit 650P Furnace Vision Graphite Furnace AAS with Zeeman background correction Product Specifications

  • Corrosion-resistant, metal housing with precision optical and furnace components
  • ZEEnit 650P
  • AC Mains Electricity
  • Ambient to 3000C (typical operation up to 3000C for graphite furnace atomizer)
  • Approx. 65 kg (instrument only)
  • Furnace Vision integrated camera, transverse heated graphite tube, patented Zeeman 3-field background correction, full automation support
  • Integrated digital LCD display
  • Fully Automatic (with optional autosampler)
  • Multiple sample capacity; up to 90 sample positions with automatic sampler (AS) compatibility
  • Graphite Furnace Atomic Absorption Spectrometer (AAS)
  • 230 V AC
  • Approx. 520 x 540 x 320 mm (without autosampler)
  • Elemental analysis of trace metal concentrations in analytical laboratories
  • 50/60 Hz
  • High precision; typically <2% RSD for standard solutions
  • Graphite furnace atomizer, Zeeman background correction system, optical bench, power supply unit
  • ppb to ppm concentrations for a wide range of elements
  • Transversely heated, platform or wall type graphite tubes
  • Compatible with manual and automatic sample injection systems
  • Programmable temperature stages for drying, ashing, and atomizing
  • High purity Argon as shielding and purge gas; optional modifier gas support
  • Environmental, clinical, food safety, pharmaceutical, metallurgical, and chemical analysis
  • Global technical service network, remote diagnostics via software
  • Automatic gas leak detection, over-temperature protection, tube breakage detection
  • Transverse Zeeman effect with 3-field magnetic modulation for superior matrix correction
  • USB, serial, and Ethernet interfaces for data transfer and peripherals
  • Photomultiplier tube (PMT) detector with high sensitivity and stability
  • Integrated camera for direct visual monitoring of sample deposition and atomization process
  • Temperature: 1035C; Humidity: 2080% (non-condensing)
  • Up to 120 samples per hour (with autosampler)
  • High-resolution double beam, Echelle monochromator, fiber-optic light guidance
  • Hollow cathode lamp and electrodeless discharge lamp (EDL) support
  • WinAAS operating software for data acquisition and instrument control

Product Description

Brand                     Analytikjena

Model                     650P

Capacity                0.94 g/L 1 %Abs (Pb 283)

CAT No                  813-0650P-2-K

Application           Spectroscopy

Zeeman AAS for graphite furnace and hydride technique. Highly sensitive trace analyzer for recurring measurement tasks, equipped with a furnace camera




Superior Matrix Correction with Zeeman 3-Field Magnetic Modulation

The ZEEnit 650P leverages patented Zeeman background correction using a transverse magnetic field and three-field modulation. This technology delivers accurate matrix correction by eliminating interferences, ensuring reliable results even in complex sample matrices and challenging applications such as environmental and clinical analysis.


Enhanced Precision with Furnace Vision and High-Resolution Optics

Equipped with an integrated camera, the Furnace Vision system enables direct visual control over sample deposition and atomization. Combined with a high-resolution double-beam, echelle monochromator, and fiber-optic guidance, this system offers outstanding sensitivity, minimizing errors during sample measurement and maximizing process transparency for users.


Full Automation and Extensive Sample Handling Capacity

The instrument supports both manual and automatic injection systems, allowing seamless adaption to laboratory workflows. With an autosampler, the ZEEnit 650P can process up to 120 samples per hour and accommodate up to 90 sample positions, ensuring high throughput and operational efficiency for busy labs.

FAQ's of Analytikjena ZEEnit 650P Furnace Vision Graphite Furnace AAS with Zeeman background correction:


Q: How does the Zeeman background correction system benefit my analyses?

A: The Zeeman 3-field magnetic modulation in the ZEEnit 650P provides superior matrix correction by effectively compensating for background absorption, especially in samples with complex matrices. This ensures higher accuracy and reliability in trace metal determinations, reducing interference that often affects results in standard AAS instruments.

Q: What is the advantage of the Furnace Vision camera in the analysis process?

A: The integrated Furnace Vision camera enables direct visual monitoring of the sample inside the graphite furnace during deposition and atomization. This allows users to optimize sample placement, assess the process in real time, and troubleshoot potential issues, ultimately enhancing analytical confidence and reproducibility.

Q: When should I use the autosampler, and what is its maximum capacity?

A: The autosampler is ideal for high-throughput laboratories or when handling numerous samples simultaneously. The ZEEnit 650P autosampler can manage up to 90 sample positions and analyze up to 120 samples per hour, streamlining workflows and reducing manual intervention.

Q: Where can the ZEEnit 650P be used for elemental analysis?

A: This instrument is well-suited for a broad range of laboratory environments, including environmental monitoring, food safety, clinical, pharmaceutical, metallurgical, and chemical analytical labs. Its precise measurements across ppb to ppm levels make it valuable for virtually any laboratory needing accurate trace metal determination.

Q: What gases and utilities are necessary for operating the ZEEnit 650P?

A: High-purity Argon gas is required for shielding and purging the graphite furnace; there is also optional support for modifier gases depending on analytical needs. The system operates on standard 230 V AC mains electricity and features robust safety monitoring for gas leaks and over-temperature events.

Q: How does WinAAS software enhance the operation of the ZEEnit 650P?

A: WinAAS offers comprehensive data acquisition, instrument control, and remote diagnostics. It simplifies sample programming, data analysis, and report generation, facilitating intuitive operation whether running routine assays or sophisticated research analyses.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Life Sciences' category



trade india member
SAASKIN CORPORATION PRIVATE LIMITED All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.